How to read the DigiQ DX3's screen

Modified on Mon, 08 May 2023 at 04:23 PM

The DigiQ DX3’s three digit LED display has three status indicators.



FAN STATUS INDICATOR 


The Fan Status Indicator and Fan Display Warble will help determine how the fire is being controlled. When there is sufficient fuel in the pit, the fan will gently puff the fire, feeding it little bursts of oxygen. When the fan is energized, the display will blink about once per second (fan warble) and the Fan Status indicator will turn on. When the pit starts to run out of fuel, the fan will run almost all of the time.


DETERMINING THE OUTPUT PERCENTAGE FROM THE FAN WARBLE


The Fan Warble is designed so that the output percentage of the fan can be determined by counting how many display blinks (warbles) occur in a given cycle as per the table below:



TIP: If the output percentage is around 80-100% for a long time, the pit may be running out of charcoal. If the output percentage is around 10% for a long time and the temperature is oscillating, close the fan damper adjustment slightly for better control.


Food Done Message


When the food temperature reaches or exceeds the food setpoint, the display will indicate that the food is done and the beeper will sound.


Over/Under Range Temperature


If the temperature goes below 32° or above 475° F on the food or pit probe, the display above will show.


Food or Pit Temperature Displays


The DigiQ DX3 can display either the Food or Pit temperature. The default is Pit. Press the Food button once to display food temperature, then press Pit to return.


 

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons

Feedback sent

We appreciate your effort and will try to fix the article